高鐵輕軌地鐵隧道專用電纜WZR-DZY22
一、執行標準standard:
企業標準Enterprise’s standard
二.適用范圍Applications:
該電纜適用于地鐵.隧道.車站等相對密閉人員集中.有很高的阻燃要求.且特別要求在燃燒時不生產濃煙,有毒害作用的鹵酸氣體及嚴禁燃燒產生“二次災害”的苛刻環境下使用。尤其適用于隧道沿線及配電柜與地鐵之間的敷設。
Suitable for subway.tunnel,station etc with crowded people wherever requires higher flame-retardant,less amount of smoke and poisonous halogen gas when burning and not cause“the second disaster”.Especially suitable for installation and laid along tunnel line.power cabinet and rai1way.
三、使用特性Properties:
1.產品型號:WZR-DZY(具體規格參見附表)
Model:WZR-DZY(detail is see the attached table)
注:①WZR(A、B)-DZY WZR(A、B)-DZY均與上型號等效。
②阻燃級別:WZRA--為A類低煙無鹵阻燃
WZRB--為B類低煙無鹵阻燃
WZR---為c類低煙無鹵阻燃
2.額定電壓750V,1500V
Rated voltage:750V.1500V
3.標稱截面O.5-400mm2
Nominal cross section area:O.5-400mm2
4.導體長期工作溫度70℃,短路過載溫度可達到130℃(5s)
Permissible long-term working temperature is 70℃.Max.working temperature of the conductors in short- circuit is 130℃.(5S)
5.電纜最小允許彎曲半徑不超過電纜直徑的15倍。
Allowed Min.bending radius are not more than 1 5 times 0f cable O.D.
6.電絕緣性能,物理機械性能優異
Possessing good electrical insulation performance,physical mechanical properties.
7.電纜阻燃性能達到GB/T18380.3-2001電纜成束燃燒試驗A、B、C類(IEC332-3)的要求
Flame-residence comforts to the requirement of GB/T1 8380.3-2001(IEC332-3)
8、低煙特性:滿足GB/T17650-1998,GB/T17651—1998的要求
Low-smoke property comforts to GB/T17650-1 998.GB/T17651—1 9989.
9、無鹵特性:(1)導電率≤10 μs/mm
(2)PH值≥4.3
Non-halogen property:(1)Conductivity≤10 μs/ram
(2)PH≥4.3
10、煙氣毒性符合GAl32準安全級的要求。
Smoke poisonous conform to GAl32.
空氣敷設長期連續負荷載流量單位:A
Continue loading current of cable laid in air
截面 mm 2Cross Section |
DZY-WZR(A 、 B)-750V |
DZY-WZR(A 、 B)-1500V |
||
接觸 Contact |
非接觸 Non contact |
接觸 Contact |
非接觸 Non contact |
|
0.5 |
7 |
9 |
6 |
8 |
0.75 |
10 |
13 |
10 |
12 |
1.0 |
15 |
17 |
1 5 |
16 |
1.5 |
19 |
22 |
1 9 |
21 |
2.5 |
26 |
29 |
25 |
27 |
4.0 |
34 |
38 |
32 |
37 |
6.O |
44 |
48 |
42 |
46 |
10 |
62 |
70 |
60 |
68 |
16 |
85 |
94 |
80 |
92 |
25 |
110 |
121 |
105 |
117 |
35 |
135 |
150 |
129 |
146 |
50 |
170 |
188 |
163 |
183 |
70 |
220 |
244 |
211 |
240 |
95 |
270 |
302 |
259 |
296 |
120 |
320 |
358 |
307 |
350 |
185 |
425 |
469 |
412 |
461 |
240 |
510 |
572 |
497 |
562 |
300 |
570 |
632 |
551 |
622 |
400 |
690 |
760 |
668 |
758 |
注:環境溫度為40:C Note:environment temperature is 40℃
地鐵隧道專用電纜結構參數表Cable construction
序號 |
標稱截面 |
線芯結構 |
電纜最大外徑 mm |
電纜參考重量 kg / km |
20 ℃ 時導體電阻 |
||
750V |
1500V |
750V |
1500V |
||||
1 |
0.5 |
16 / 0.2 |
3.60 |
4.20 |
14 |
16 |
40.1 |
2 |
0.75 |
19 / 0.23 |
3.80 |
4.40 |
17 |
19 |
25.6 |
3 |
1.0 |
19 / 0.26 |
4.10 |
5.00 |
23 |
26 |
19.9 |
4 |
1.5 |
19 / 0.32 |
4.50 |
5.30 |
31 |
33 |
12.8 |
5 |
2.5 |
16 / 0.2 |
5.20 |
6.00 |
40 |
44 |
7.74 |
6 |
4.0 |
19 / 0.23 |
6.00 |
6.80 |
61 |
66 |
4.97 |
7 |
6.0 |
19 / 0.64 |
6.70 |
7.40 |
85 |
91 |
3.35 |
8 |
10 |
49 / 0.52 |
8.30 |
9.10 |
138 |
150 |
1.95 |
9 |
16 |
49 / 0.64 |
9.40 |
10.8 |
196 |
210 |
1.24 |
10 |
25 |
98 / 0.58 |
11.3 |
12.1 |
296 |
313 |
O.78 |
11 |
35 |
133 / 0.68 |
12.9 |
13.7 |
414 |
434 |
0.557 |
12 |
50 |
133 / 0.68 |
14.6 |
15.0 |
548 |
570 |
O.414 |
13 |
70 |
189 / 0.68 |
16.0 |
16.4 |
760 |
786 |
0.227 |
14 |
95 |
259 / 0.68 |
18.2 |
18.6 |
993 |
1021 |
0.210 |
15 |
120 |
259 / 0.76 |
20.2 |
20.6 |
1250 |
1288 |
O.164 |
16 |
150 |
336 / 0.74 |
22.2 |
22.6 |
1538 |
1576 |
0.132 |
17 |
185 |
427 / 0.85 |
24.8 |
25.2 |
1846 |
1901 |
0.108 |
18 |
240 |
427 / 0.85 |
28.4 |
28.8 |
2446 |
2468 |
0.0817 |
19 |
300 |
518 / 0.85 |
32.2 |
32.8 |
2995 |
3042 |
O.0654 |
20 |
400 |
703 / 0.85 |
36.4 |
36.8 |
4530 |
461 3 |
0.0490 |
編制說明Directions:
1.低煙無鹵阻燃聚烯烴絕緣地鐵隧道專用電纜連續負載電流是依據IEC-287電纜載流量計算標準進行計算的,并通過修正確定。
Continuous loading current of cable is calculated per IEC-287
2.此地鐵隧道專用電纜的長期工作溫度不超過70℃。
Long-term working temperature is not more than 70℃.
3.布線方式分為接觸與非接觸兩種,其中非接觸指電纜間的相互距離大于二倍的電纜外徑.接觸即指電纜相互靠在一起或相互間距小于二倍的電纜外徑。
Laid method:contact and non contact.Non contact laid means the distance between the laying cable is more than 2 times of cable O.D.Contact laid means the distance between the laying cable is not more than 2 times of cable O.D.
4.周圍環境溫度以40℃作為基準溫度。
Environment temperature is supposed 40℃ as basic temperature
環境溫度變化修正系數表
The revised coefficient of the environmental temperature change
載流量校正系數 Loading current of cable revised coefficient |
|||||||||
環境溫度 E nvironment |
10 |
1 5 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
工作溫度 temperature Working temperature 70 ℃ |
1.41 |
1.35 |
1.29 |
1.22 |
1.15 |
1.08 |
1.00 |
O.93 |
O.88 |
電纜敷設于塑料槽中載流量修正系數表
The revised coefficient of the cable loading current lay in plastic flume
電纜層數 |
同時工作系數 K Coefficient K |
||
1.00 |
O.80 |
0.50 |
|
1 |
0.64 |
0.80 |
0.95 |
2 |
0.50 |
0.75 |
0.90 |
3 |
0.45 |
O.70 |
0.85 |
4 |
0.40 |
0.65 |
0.80 |
注:K系指在塑料槽中有負荷電纜根數與總的電纜根數之比(負荷電纜我指通是流發熱電纜,信號線除外)。
Note. k= Loading current cables
Total number of the cables
(Loading current cables means cables that generating heat when working excet for signal line)
電纜穿管敷時載流量修正系數表
The revised coefficient of the cable loading current lay in tube
穿管根數 |
修正系數 |
2 ~ 4 |
0.80 |
5 ~ 8 |
0.60 |
9 ~ 12 |
0.50 |
12 以上 |
0.45 |
注:
1.穿管根數指有負荷發熱的電纜根數。
2.穿管線的體積不超過管體積的40%。
3.當管并列敷設時乘0.95修正系數。
Note:
1) The number of the cable in tube means the number of the cables which generates heat while loading.
2)The cable’s volume is not more than 40% of the rube’s volume.
3)When cable laid stand by stand,multiply the revised coefficient with 0.95
萬邦特種電纜型號查找導航
注:看到所需要的電纜型號可直接點進去到文章頁面
第一章:特種電纜
第二章:耐高溫電纜
1.AFR-250 2. KFF47 KF47 KF47P 3.AFP AFPF AF4 AF46 4.ZR-KFV ZR-KFVP ZR-KFV22 ZR-KFFP 5.AFSPF-200 6.KFV KFVP KFVP22 KFVRP22 7.AF250 8.AFPXR-200 9.F2H8 F46H3 F4H4 10.ZR-F46V KF46GR KFGRP 11.YGC-F46R ZR-F46-22 12.AF46R AF46RP 13.F46 ZR-F46 14.AFHBRP 15.FF22 ZR-FV ZR-FVR 16.KHF46 17.GN500-01 GN500-02 GN500-03 GN500-04 GN500-05 18.KHFRP 19.IA-DJFPF46P 20.KHF46RP KHF46P KHF46R 21.AFRPF 22.KFF KFFR KFFP 23.ZR-KFVR 24.DJFVP DJFPV DJFPVP DJFP2V DJFVP2 DJFP2VP2 DJFFP DJFPF DJFPFP DJFFP2 DJFP2F DJFP2FP2 DJFVRP、DJFPRV DJFPVRP DJFP2RV DJFVRP2 DJFP2VRP2 DJFFRP DJFPRF DJFPFRP DJFFRP2 DJFP2RF DJFP2FRP2 25.KHF46FRP ZR-KHF46VRP KFF22 KFF22P KFFP22 26.YGCF46 YGCF46R
第三章:低煙無鹵電纜
1. WDZ-KYJYP2-23 2.WDZN-KYJY WDZN-KYJY22 WDZN-KYJYP2-22 3.WDZN-RYJS 4.WD-CYY WD-CYYC WD-TYY 5.WDZN-KYJ(F)Y WDZN-YJ(F)Y23 6.WDZ-KYJYP WDZ-KYJYRP WDZ-KYJEP 7.WDZN-KYJYP2-22 8.WDZN-RYJS WDZN-BVVB WDZN-BYJ 9.WDZ-DCEYJR-125 10.WDZN-KYJE WDZANH-KYJEP 11.WD-NH-YJE 12.WDZ-RYJSP13.WDZ-KYJY33 WDZN-YJY23 WDZN-KYJYP2-23 WDZ-KYJYP2 14.WDZN-KYJYP 15.WDZ-DJYPYPR 16.WLD-KJEGP2-22 17.WDZN-YJY22 18.WDZA-KYJVRP2 WDZA-YJV22 WDZA-KYJVP2 WDZA-DJYJPVP 19.WDZ-RYY WDZ-RYYP 20.WDZN-KYJE WDZN-KYJE22 WDZN-KYJEP2
第四章:補償導線(電纜)
1. ZR-KX-GVPVPR 2.KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR 3. KX-HA-FGRP 4.ZRC-KX-YP2VP2 5.KX-FPG-1 KX-FPV-2 KX-FPF-3 6.KX-HF4PB KX-HF4PR 7.KX-GS-FP1FP1 8.KX-GA-VVRP KX-HA-FVRP 9.KX-HA-FFP 10.KX-FF46-RP1 KX-HA-FFRP 11.SC-G-VV SC-G-VPVPR SC-H-FFR SC-G-VPVP32 12.KX-HF4P EX-HF4P KC-HF4P SC-HF4P 13.TX-HA-FFP 14.JHKX-HF46PF46P 15.ZR-SC-G-VVP 16.KX-HA-FPFP 17.ZR-KC-HA-FF46P 18.KC-GB-VVP KX-GS-VVRP
第五章:硅橡膠電纜
1. JHXG 2.GFR GFP GFRP 3.YGCB 4.KFGR KFGRP KF46G KF46GP 5. YGZP 6.YGCPB YGGB YGCB-AF46R 7.ZR-YGGRP ZR-JGGRP 8.KHGPG KHGPG KHG30G KHPG20G 9.RGG YGZ YG 10.FDGG-40 FDGU-55 11. RGGP KF46GR KF46GRP 12.AGR 13.NH-KGGRP NH-KFGRP 14.YGCP 15.IMKGG IMKGGP 16.HGVF HGVFP 17.KFGD KFGDP 18.YGG 19.JGGFR 20.DJFGP 21.BPGGP BPGGP2 BPGGPP2 BPGGP3 BPGVFPP2 22.FYGC 23.AGRP 24.AGG 25.YGC YGC22 YFG YGC-F46R 26.ZRC-DPGPGRP 27.YGVFZ 28.JGGP ZR-JGGP 29.YGCR JGGR 30.JG JGG
第六章:扁電纜
1. ZR-YSFVBR ZR-YSFVBRJ ZR-YSFVBRZ ZR-YSFVBRJP 2.YFFB-G YVFB-G 3.YFVB 4.CEFBR 5.YEFB YEFBP YEFBJ YEURB YEURBP YEURBJ 6.YFFPB YVFPB YFFBP YVFBP 7.YCB YCBP 8.YGPB-6KV YGPB-10KV 9.ZR-YFFB ZR-YVFB 10.YBF 11.YEFRBG YGFRBG 12.H25VVH6-F 13.YGGB-J YGCB-VFR-J YGCB-J YGVFCB-J YFGCB-J 14.YBP-J 15.YB 16.EFB EFBP EFBJ EURB EURBP EURBJ 17.YVVB TVEB YFEB YGFB 18.YKVFBG YFFRBP 19.YGCB-L 20.YJGCFPB 21.YQB YQSB YQSFB YQFB 22.YCFB YCFBG 23.YBZ 24.TVVB KGGB YGCB 25.YEEB YFEB 26.YFFB-FJL 27.GKFB 28.TVVBPG
第七章:電機引接線
1. JZQB.F-1140V 2.JF46 3.JZ 4.JHGG 5.JGG 6.JHGX 7.JEH 8.JV 9.JF 10.JBF JBHF 11.JBQ 12.JXN 13.JXF 14.JH 15.JE 16. JYJ-125 17.JYJ-150 18.JO-150
第八章:鐵路機車電纜
1. WDZ-DCYJ-125 2.DCEH/3-100 3.CXVF DCXVF DCXVFP DCXHF DCXHFP 4.DC-WDZB-EPR-1.8kV 5.WDZ-DCYJR 6.SLEX-125 SPLEX 7.DCEYH 8.DCEYHR 9.DCXF DCEH 10.DT-KAFPR 11.DWZR-PGYP2/23 DWZR-PGY23 12.WDZ-DC-H-90 WDZ-DC-ZP-H-90 13.WDZ-DCK-125 WDZ-DCKP-125 14.WDZ-DCYG-180 WDZ-DCYGP-180 15.DCH/3 DCXF/2 DCEH/3 16.WDZ-WL1 WDZ-WL2 WDZ-WL3 17.FY/WDZA-YJE FY/WDZA-YJE FY/WDZA-EJEJ FS/FY/WDZA-EJE23 18.JVN JVNP 19.DC-WDZA-EYR DC-WDZX-YJY DC-WDZA-FF 20.NSGAFOU 21.DVYJVR DCEFR WDZ-DCEFR FSZ-WDZ-DCYJYR 22.WDZA-DCYJTY WDZA-DCYJTYR 23.HSGCEVMP WDZ-DCEVMP HSGCEVMNH WDZ-DCEVMNH 24.DCYH DCYHR DCYHP DCEYHP
本頁只是一小部分電纜型號可查找,如需其它型號請到首頁產品中心或新聞中心仔細查找。如需幫助請撥打熱線電話:18909608445 0550-7723889